Profiles over time
A budget adds a number up once. A profile adds it up over time: a mission, an orbit, a working day, cut into phases. Each phase says what the system draws and gives while it lasts, and a stock keeps the running total: a battery, a tank, a data recorder, a cost.
Extension — not covered by the 1.0 stability promise (
profile; the core)
A first profile#
profile mission "First hours" {
phase launch 10min { power 40W }
phase cruise 6h { power 12W; solar 18W }
stock battery "Battery" {
capacity 100Wh
start 50%
flow solar - power
}
}
requirement REQ-BAT "Battery above 20 %" { limit mission.battery >= 20% }
A phase has a name and a duration (10min, 6h, 24h).
What it writes is the value of a quantity during the phase, under any name:
power 40W, solar 18W. A quantity a phase does not write is zero in it,
unless the parts of the system give it (below).
A stock is a level that its flow fills and empties.
The flow is a formula over the profile's quantities; in each phase the level
moves by the flow times the phase's duration.
With a capacity the level stays between empty and full, and start says
where it begins (a level, or a share of the capacity; empty by default).
$ archec profile main.arche
profile mission — First hours: 6h 10min
phase lasts power solar battery
launch 10min 40W 0W −6.667Wh
cruise 6h 12W 18W +36Wh
power 12W … 40W, 12.757W on average
solar 0W … 18W, 17.514W on average
battery 50Wh (50%) at the start, 79.333Wh (79.333%) at the end — holds 100Wh
lowest 43.333Wh (43.333%) at the end of launch, 10min in; highest 79.333Wh (79.333%) at the end of cruise, 6h 10min in
✓ REQ-BAT mission.battery lowest 43.333Wh (43.333%) at the end of launch, 10min in; the limit is >= 20%
archec profile main.arche --svg build/ also writes build/mission.svg: every
stock and every quantity over the timeline, each on its own scale, with the
capacity and the limits drawn.
The parts add up, mode by mode#
A quantity a phase does not write is added up over the parts of the system,
the way a budget is: each part's power 4W, a repeated part once
per copy. A number under a name of your own is a free property:
prop solar = 28W.
A phase names the operating mode the system is in.
Only the components active in that mode are counted, and the mode gives a part
its number in that mode with set:
component Computer { power 4W }
component Radio { power 1W }
component Heater { power 0W }
component Panels { prop solar = 28W }
system Sat {
part obc: Computer
part radio: Radio
part heater: Heater
part panels: Panels
budget power 20W
}
operating-mode SUNLIT { initial; set radio.power = 12W }
operating-mode ECLIPSE { set heater.power = 6W; set panels.solar = 0W }
profile orbit {
of Sat
repeat 15
phase sunlit 60min { mode SUNLIT }
phase eclipse 35min { mode ECLIPSE; set radio.power = 0.5W }
stock battery { capacity 40Wh; start 100%; flow solar * 0.9 - power }
}set part.name = valuein an operating mode is the part's number in that mode. On a part that holds parts it stands for all of them. The mode's ownbudgetis added up with it.setin a phase does the same for that phase only, over what the mode says.ofnames the system, when the model has several.repeat 15runs the timeline fifteen times, one after the other.- Each phase's total is checked against the
budgetof its mode and of the system (profile-over).
A phase can hold phases. It then lasts what they last, repeat times, and
what it says (mode, set, a quantity) holds for all of them:
profile year {
repeat 365
phase night 10h { light 0W }
phase day {
repeat 7
phase on 1h { light 120W; tariff 0.03EUR }
phase off 1h { light 0W }
}
stock energy { unit kWh; flow light }
stock cost { flow tariff; per h }
}
What a flow adds up to#
The one conversion a profile makes is a rate times a time.
| The flow is | The stock holds |
|---|---|
a power: µW, mW, W, kW, MW |
an energy: J, kJ, Wh, kWh |
a current: µA, mA, A |
a charge: C, mAh, Ah |
a bitrate: bps, kbps, Mbps, Gbps |
data: bit … Mbit, B … TB, KiB … GiB |
a volume flow: L/s, L/min, m³/s |
a volume: mL, L, m³, cm³, mm³ |
a speed: m/s, km/h |
a length: mm, cm, m, km |
The stock's unit is its capacity's, or its start's; a stock with neither says
it (unit kWh). For anything else, per says the time the flow is given for:
with per h, a cost whose flow is 12EUR grows by 12 EUR an hour.
Nothing else is converted. Every value of one quantity is written in one unit
across the profile; a part's power 300mW beside others in W is reported
and not counted (profile-unit), as a budget does.
Limits, and what proves them#
A requirement bounds a profile with the limit it bounds geometry with:
| Written | Holds when |
|---|---|
limit mission.battery >= 20% |
the stock never goes under 20 % of its capacity, over the whole profile |
limit mission.battery >= 16Wh |
the same, as a level |
limit mission.power <= 45W |
the quantity is at most 45 W in every phase |
limit mission.eclipse.power <= 20W |
in that phase (orbit.eclipse for a phase inside a phase) |
limit mission.eclipse.battery >= 30% |
the stock, during that phase |
>= and > look at the lowest value, <= and < at the highest.
archec check says when a limit is not held (profile-limit), with the value
and the phase. archec profile records each limit as evidence, and
archec status shows it under its requirement:
REQ-BATTERY The battery stays above 30 %
✓ profile day.battery the model just now lowest 33Wh (82.5%) at the end of eclipse, 1h 35min in; the limit is >= 30%
The record is out of date when a number the profile adds up has changed: a
phase, a mode's set, a part's power. A limit never worked out reads
never measured: archec profile.
A stock that runs empty is reported as information (profile-empty), with how
much was drawn from it that was not there; one that is full says how much did
not fit. Neither fails by itself: a limit says what the system needs.
examples/cubesat is a small satellite over a
day in orbit: three modes, a battery and a recorder, three requirements.
Limits#
- A profile is a coarse analysis: every number is constant within a phase.
It is not a solver. A battery whose voltage sags, or a tank that drains
faster when full, is an
equationandarchec physics. - A profile is not simulated: no behaviour runs, no state machine changes the mode. The phase says the mode.
- The operating mode is the system's. A part has no mode of its own; a phase
gives a part another number with
set. - Quantities add up (
sum). A quantity that is a maximum over the parts (budget temperature max 85°C) is not profiled. - The longest unit of time is the hour: a day is
24h, a yearrepeat 365. - Units declared by the project (
unit) are not integrated: useper. - A profile runs through 200000 phases at most.
- Arche has no profile:
archec profileand the linter work it out; nothing is written to the Arche project. - A requirement's